INTELIA
Level 4 (Water Circuit) [LED No Water + Error + Double + No Beans ON]
Description:
Verify the water circuit component: fl ux meter, pump, electro valve, brewing unit
Action:
Turn on and off actuators along water and coffee beverage circuit.
Start condition (water tank full, BU, dump box, door closed)
LED
OK
Press one time Hot Water button to open electro valve
LED
OK
Press Epresso button to turn on pump
LED
During the test
OK
ERROR (no fl ux meter feedback)
Press one time Hot Water button to close electro valve
LED
OK
Move BU to work position. Press Coffee button to move BU to work position
LED
During the test
OK
Work position not reached
Overcurrent (with or without BU)
Move BU to home position. Press Steam button to move BU to home position
LED
During test
OK
Home position not reached
Overcurrent (with or without BU)
Move BU to rest position. Press Calc Clean button to move BU to rest position
LED
OK
Press ON/OFF button moves to next level
On ERROR verify:
Cable connection
Power supply
Saeco International Group
ON/OFF
Hot water
OFF
OFF
ON/OFF
Hot water
ON
ON/OFF
Hot water
ON/OFF
Hot water
OFF
ON/OFF
Hot water
ON/OFF
Hot water
ON/OFF
Hot water
Rev. 03
05 TROUBLESHOOTING
Espresso
Coffee
OFF
OFF
Espresso
Coffee
Espresso
Coffee
BLINK
ON
ON
Espresso
Coffee
Espresso
Coffee
BLINK
ON
ON
ON
Espresso
Coffee
Espresso
Coffee
BLINK
Steam
Calc clean
OFF
OFF
Steam
Calc clean
Steam
Calc clean
OFF
OFF
ON
Steam
Calc clean
Steam
Calc clean
OFF
OFF
ON
BLINK
Steam
Calc clean
BLINK
OFF
ON
OFF
ON
ON
ON
BLINK
Steam
Calc clean
BLINK