en | RADION glassbreak
The specified range of the sensor has been established for worst-case conditions. While the
sensor will likely function at additional range, it may miss a minimum output break, or room
acoustics may change at some future time, bringing the sensor range back into normal 20 ft.
(6 m) conditions. Do not exceed the rated range of the sensor, regardless of what the tester
shows.
5.2.2

Hand clap test

Operational status of the glassbreak can be verified by performing a simple hand clap test to
ensure proper functionality of the sensor.
Performing the hand clap:
1.
2.
3.
5.3

Low battery

When a low battery state is detected, the detector measures the battery, and sends a report
to the receiver/control panel.
5.4

Wall Tamper Tab

Use the wall tamper tab to activate an alarm when the glass break has been removed from the
wall.
5.5

Maintenance

Clean the cover with a damp (water) cloth as needed to keep it free of dust and dirt. Always
test the sensor after cleaning it.
02.2014 | 01 | F.01U.261.835
Hand clap loudly under the sensor. The LED blinks twice.
Verify that the LED blinks twice.
Performing this simple test verifies that the microphone is operating, and that there is
power to the sensor.