Getting Started
1.12
Emulation Selection
The following emulations are included in the PM Ser/Par:
$
EPSON LQ / ESC/P2
$
IBM ProPrinter XL 24
$
IBM ProPrinter XL 24 AGM
$
EPSON LQ / ESC/P2
To change from one emulation to another, follow the procedure below. The ex-
ample shows the keys to press along with the display information for a change
from EPSON LQ / ESC/P2 in Macro 1 to IBM ProPrinter in Macro 2.
Switch the printer ON. The display shows READY 1 ELQ.
KEY
[OFFLINE]
[MACRO SELECTION]
(hold the key down and the available marcos are scrolling in the
display and stop pressing with selected Macro 2)
[ONLINE]
The information READY
emulation of this macro, for example:
1 ELQ
2 IPP
3 AGM
4 ELQ
A "Macro" is a summary of application specific parameter settings. It is
Note:
possible to have a total of four macros, each with a different summary of
VALUE settings.
The settings selected and confirmed are only active until the printer is
switched off. In order to prevent losing your new settings you can save
them using the function SAVE MENU (see chapter 2.4.3 How to Save
Settings.
1-26
2 IPP indicates the selected macro and the
Macro 1 with Epson Emulation
Macro 2 with IBM Proprinter Emulation
Macro 3 with IBM Proprinter AGM Emulation
Macro 4 with Epson Emulation.
in Macro 1 (Default)
in Macro 2
in Macro 3
in Macro 4
DISPLAY
LOCAL
MACRO 2
READY
1 ELQ
U