Installations; Indoor Unit Installation - York YKCA 18 Installation & Owner's Manual

Minisplit cassette air conditioner
Table of Contents

Advertisement

INSTALLATIONS

CAUTIONS
Location in the following places may cause malfunction of the machine. (If unavoidable, please consult your local dealer)
a. There is petrolatum existing.
b. There is salty air surrounding (near the coast).
c. There is caustic gas (the sulfide, for example) existing in the air (near a hot spring).
d. The Volt varies violently (in the factories).
e. In buses or cabinets.
f. In kitchen where oil or gas are present.
g. There is strong electromagnetic wave existing.
h. There are inflammable materials or gas.
i. There is acid or alkaline liquid evaporating.
j. Other special conditions.
NOTICES BEFORE INSTALLATION
1. Select the correct carry-in path.
2. Move this unit as originally packaged as possible.
3. The air conditioner must be electrically insulated according to the relevant standards to electrical appliances.
1. The indoor unit
• There is enough room for installation and maintenance.
• The ceiling is horizontal, and its structure can endure the weight of the indoor unit.
• The air outlet and the air inlet are not impeded, and the influence of external air is the least.
• The air flow can reach throughout the room.
• The connecting pipe and drainpipe could be extracted out easily.
• There is no direct radiation from heaters.
2. The outdoor unit
• There is enough room for installation and maintenance.
• The air outlet and the air inlet are not impeded, and cannot be reached by strong wind.
• It must be a dry and well ventilating place.
• The base is flat, level and can support the weight of the outdoor unit without vibration.
• Your neighborhood will not feel uncomfortable with the noise or expelled air.
• There is no leakage of combustible air.
• It is easy to install the connecting pipe or cables.
• Determine the air outlet direction where the discharged air is not blocked.
• A place is free from a leakage of combustible gases.
In the case that the installation place is exposed to a strong wind such as a seaside or high position, secure
the normal fan operation by putting the unit lengthwise along the wall or using a duct or shield plates.
• If possible, do not install the unit which is exposed to direct sunlight.
• If necessary, install a blind that does not interfere with the air flow.
• During the heating mode, the water drained off the outdoor unit. The condensate should be well drained away by
the drain hole to an appropriate place so as not to interfere other people or public.
• Select the position that will not be subject to snow drifts, accumulation of leaves or other seasonal debris. It is
important that the air flow for the outdoor unit is not impeded as this will result in reduction in heating or cooling
performance.

INDOOR UNIT INSTALLATION

1. INSTALL THE MAIN BODY
A. The existing ceiling (to be horizontal)
a. Cut a square hole of 880 x 880 mm. in the ceiling according to the shape of the installation paper board.
(Refer to chart 3, 4)
• The center of the hole should be at the same position of that of the air conditioner body.
• Determine the lengths and outlets of the connecting pipe, drainpipe, and cables.
• Strengthen the ceiling as necessary to avoid vibration.
8
ENGLISH
YORK INSTALLATION & OWNER'S MANUAL (EN) 035M80090-000