YKDAxxFS-AAR YKDAxxFS-ACR YKDAxxFS-ADR consistent reliability in product, Outdoor YKJAxxFS-AAR YKJAxxFS-ACR YKJAxxFS-ADR service and support through superior quality, service culture YKEAxxFS-AAR YKEAxxFS-ACR YKEAxxFS-ADR Indoor and distinctive technology. YKKAxxFS-AAR YKKAxxFS-ACR YKKAxxFS-ADR ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
For proper performance, operate the unit in temperature and humidity ranges indicated in this manual. If the unit is operated beyond these conditions, it may cause abnormal functions of the unit or dew dripping from the unit. ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
3. Optimum performance will be achieved within these operating temperature. All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner you purchased. The actual shape shall prevail. ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
Rotary Scroll Height 1245 1245 Dimension Width Depth Weight Type Flare+Nuts inch Pipe Size Liquid inch Remark: The above design and specifications are subject to change without prior notice for product improvement. ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
DIMENSIONS INDOOR UNIT YKEA-YKKA 18-48 4-Install hanger Gas side Liquid side Control box Pump inspection hole Drain outlet YKKA 18-48 YKKA 18-24 YKKA 48 ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
Page 7
OUTDOOR UNIT YKDA-YKJA 18 YKDA-YKJA 24 301.5 560.1 141.5 YKDA-YKJA 48 ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
• The center of the hole should be at the same position of that of the air conditioner body. • Determine the lengths and outlets of the connecting pipe, drainpipe, and cables. • Strengthen the ceiling as necessary to avoid vibration. ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
Page 9
10 ~ 12 mm. (Refer to chart 5). • Locate the air conditioner firmly by adjusting the nuts. Body Ceiling Chart 6 Chart 7 ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
Page 10
(6) Relocate the installation cover. a. Fasten the rope of installation cover on the bolt of the installation cover. (Refer to chart 15-left) b. Press the installation cover into the panel slightly. (Refer to chart 15-right) ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
• The minimum distance between the outdoor unit and obstacles described in the installation chart does not mean that the same is applicable to the situation of an airtight. Leave open two of three directions A, B, C. Chart 16 ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
Page 12
• In some regions, it is necessary to heat the bottom of the condensate drainage pan and the condensate drainage piping to avoid ice formation, and resulting ice build-up in the fan compartment (heater strip must be at least 25 W/m). ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
Insulation material (inside) Board Board No insulation material inside, only removal board Removal with pincher Removal with pincher Removal with pincher or incise with knife Commissure Commissure Insulation material (inside) Board Board ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
Page 14
Note: 1. All ducts must be completely heat-insulated. 2. The following phenomena are not allowed when installing duct: A) Bend too much B) Too many bender C) Diameter reduce Wrong Wrong Wrong ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
The diameter of a common drainage line must be sufficient to accommodate the condensate flow from the units connected to it. Verification of condensate water drainage: Fill the drain pan and observe evacuation. ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
2. Connect the line to a vacuum pump and pump down to 5 Pa. 3. When pump down is finished, wait 15 minutes to detect potential circuit leakage. Open service valves on the outdoor unit. ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
HIGH for 30 minutes. The remote controller operation is disabled. 3. OFF The RUN lamp goes off. The air conditioner is OFF while the remote controller operation is enabled. ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
4. Clean the air filter (Vacuum cleaner or pure water may be used to clean the air filter. If the dust accumulation is too heavy, please use soft brush and mild detergent to clean it and dry out in cool place). ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
10.Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Disconnect the unit with power and then re-connect the unit with power again. Push the ON/OFF button on the remote controller to restart operation. ENGLISH YORK INSTALLATION & OWNER’S MANUAL (EN) 035M80090-000...
Authorized Representative: CM Choi Shipping Manager YORK International (Northern Asia) Ltd. 15/F., Tower II, World Trade Square, 123 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong Telephone: (852) 2331 9286 Fax: (852) 2331 9840 Technical Service Division: Telephone: (852) 2331 9286 Fax: (852) 2304 0068...