DECLARATION OF CONFORMITY

Type of Equipment
Brand Name
Type Designation
Application of Council
Directive (s)
The following harmonized standards have been applied:
Standard (s)
EN 60335-1:2002+A11
EN 60335-2-40:2003
EN 50366:2003
EN 55014-1/A2:2002
EN 55104-2/A1:2001
EN 61000-3-2:2000
EN 61000-3-3:1995+A1
The product complies with the harmonized European safety standards and harmonized EMC standards listed above.
We have internal production control system that ensures compliance between the manufacturer products and the technical documentation.
The product is CE mark.
We declare under our sold responsibility that the equipment follows the provisions of the Directives stated above.
Authorized Representative:
CM Choi
Shipping Manager
YORK International (Northern Asia) Ltd.
15/F., Tower II, World Trade Square, 123 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong
Telephone: (852) 2331 9286 Fax: (852) 2331 9840
Technical Service Division: Telephone: (852) 2331 9286 Fax: (852) 2304 0068
This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause injury!
All work must only be carried out by competent persons using suitable protective clothing and safety precautions.
Read the Manual
1. Isolate all sources of electrical supply to the unit including any control system supplies switched by the unit. Ensure that all points
of electrical and gas isolation are secured in the OFF position. The supply cables and gas pipework may then be disconnected and
removed. For points of connection refer to unit installation instructions.
2. Remove all refrigerant from each system of the unit into a suitable container using a refrigerant reclaim or recovery unit. This
refrigerant may then be re-used, if appropriate, or returned to the manufacturer for disposal. Under No circumstances should
refrigerant be vented to atmosphere. Where appropriate, drain the refrigerant oil from each system into a suitable container and
dispose of according to local laws and regulations governing disposal of oily wastes.
3. Packaged unit can generally be removed in one piece after disconnection as above. Any fixing down bolts should be removed and
then unit lifted from position using the points provided and equipment of adequate lifting capacity. Reference MUST be made to the
unit installation instructions for unit weight and correct methods of lifting. Note that any residual or spilt refrigerant oil should be
mopped up and disposed of as described above.
4. After removal from position the unit parts may be disposed of according to local laws and regulations.
DECLARATION OF CONFORMITY
Air Conditioners
YORK
YKEA-YKDA 18/24/36/48FS, YKKA-YKJA 18/24/36/48FS, YKEB-YKDB 12/18/24/30/36/48FS,
YKKB-YKJB 12/18/24/30/36/48FS, YKKC-YKJC 12/18/24/30/36/48FS
EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC and Machine Safety Directive: MSD
INSTALLATION, REMOVAL AND DISPOSAL
Risk of electric shock
Unit is remotely controlled
and may start without warning