OUTDOOR UNIT INSTALLATION

CAUTIONS
• Keep this unit away from direct radiation of the sun or other heaters.
• If unavoidable, please cover it with a shelter.
• In places near coast or with a high attitude where the wind is violent, please install the outdoor unit against
the wall to ensure normal performance.
Use a baffle when necessary.
• In the case of extremely strong wind, please prevent the air from flowing backwards into the outdoor unit.
(Refer to chart 16)
• Locate the outdoor unit as close to the indoor unit as possible.
• The minimum distance between the outdoor unit and obstacles described in the installation chart does not
mean that the same is applicable to the situation of an airtight. Leave open two of three directions A, B, C.
Water-receiver
4
Outlet foam
Panel foam 2
Fan
Chart 16
Leakage
Ceiling
Pollution
Water condensation
Chart 13
Gap no allowed
Chart 14
Installation
cover's rope
tap screw
Chart 15
YORK INSTALLATION & OWNER'S MANUAL (EN) 035M80090-000
Loosen upper nut
Adjust lower nut
Slide the four slider in
the corresponding channel
when installing the cover