2-7. INTERNATIONAL
ELECTRICAL
REQUIREMENTS
2-6
Units being used outside the United States may not be shipped
with the power cord attached to the unit because of the different
wiring codes. The fryers are available from the factory wired for
208, 240, 380 and 415 volts, 3 phase, 50 Hertz service. A terminal
block is mounted inside the fryer for the cable wiring. A decal on
the inside of the right side panel will help in the wiring of the unit.
CE units require a minimum wire size of 4mm to be wired to
the terminal block. If a flexible power cord is used, it must be
HO7RN type.
To install the power cord, follow these procedures:
1. Remove the right side panel of the unit.
2. Install the cord, with a strain relief, to the junction box.
3. Attach the wires to the terminal block according to the wiring
diagram on the side panel.
4. Pull the slack out of the cord and thread it down through the
the clamp on the frame, at the rear, left leg of fryer. Then run
the cable under the frame and out the rear of the fryer, so it
doesn't interfere with the filter drain pan.
The filter drain pan must be as far back under fryer as
it will go, and the cover in place. Be sure the hole in the
cover lines up with the drain before opening the drain.
Failure to follow these instructions causes splashing of
shortening and could result in personal injury.
5. Wiring the fryer is now complete.