Technical Specifications - Polar Electro CS400 User Manual

Cycling computer
Hide thumbs Also See for CS400:
Table of Contents

Advertisement

ENGLISH
Note that in addition to exercise intensity, medications for heart conditions, blood pressure, psychological
conditions, asthma, breathing, etc., as well as some energy drinks, alcohol, and nicotine may also affect
heart rate.
It is important to be sensitive to your body's responses during exercise. If you feel unexpected pain or
excessive fatigue when exercising, it is recommended that you stop the exercise or continue at a lighter
intensity.
Notice to individuals with pacemakers, defibrillators or other implanted electronic devices. Individuals
who have a pacemaker use the Polar cycling computer at their own risk. Before starting use, we always
recommend a maximal exercise stress test under a doctor's supervision. The test is to ensure the safety
and reliability of the simultaneous use of the pacemaker and the Polar cycling computer.
If you are allergic to any substance that comes into contact with your skin or if you suspect an allergic
reaction due to using the product, check the listed materials in Technical Specifications. To avoid any
skin reaction to the transmitter, wear it over a shirt, but moisten the shirt well under the electrodes to
ensure flawless operation.
The combined impact of moisture and intense abrasion may cause a black color to come off the transmitter's
surface, possibly staining light-colored clothes. If you use insect repellent on your skin, you must ensure that it
does not come into contact with the transmitter.

Technical Specifications

Cycling computer
The wrist unit is a class 1 Laser Product
Battery life:
Battery type:
Battery sealing ring:
Operating temperature:
Materials:
Watch accuracy:
Accuracy of heart rate monitor:
Heart rate measuring range:
Current speed display range:
Altitude display range:
Ascent resolution:
Cycling computer limit values
Maximum files:
Maximum time:
Maximum laps:
Total distance:
Total duration:
Total calories:
Total exercise count:
Total ascent:
Transmitter
Battery type
Battery life
Battery sealing ring
Operating temperature
Connector material
Strap material
Water resistance
Polar WebLink using IrDA Communication, Polar ProTrainer 5™
System Requirements:
48
Customer Service Information
Average 1 year (1h/day, 7 days/week)
CR 2354
O-ring 20.0 x 1.0 Material: silicone
-10 °C to +50 °C / 14 °F to 122 °F
Thermoplastic polymer
Better than ± 0.5 seconds / day at 25 °C / 77 °F temperature.
± 1% or 1 bpm, whichever larger. Definition applies to stable conditions.
15-240
0-127 km/h or 0-75 mph
-550 m ... +9000 m / -1800 ft ... +29500 ft
5 m / 20 ft
99
99 h 59 min 59 s
99
999 999 km / 621370 mi
9999h 59min 59s
999 999 kcal
9999
304795 m / 999980 ft
CR 2025
Average 700 hours of use
O-ring 20.0 x 1.0 Material FPM
-10 °C to +50 °C / 14 °F to 122 °F
Polyamide
35% Polyester, 35% Polyamide, 30% Polyurethane
30 m (Suitable for bathing and swimming)
PC
Windows® 2000/XP (32bit)