4.3.3 ADDING VENT SECTIONS

Add chimney sections, according to the manufacturers installation instructions. The chimney must extend at
least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof, building or
obstacle within 10 feet horizontally.
3 FT
MIN

4.3.4 INSTALLING "B" VENT

ADAPTER INSTALLATION:
Remove the spill switch bracket from the rear of the
adapter.
Gently pull the two wire terminals (located inside the 7" fl ue
collar at the top of the appliance) out approximately 8".
Bring the wires through the lower hole in the adapter and
out the spill switch opening. To pass the wires through
the hole more easily, temporarily take the two terminals
together.
With the spill switch opening aligned to the back of the
appliance, take hold of the adaptor base and push the
crimped edge into the appliance fl ue collar.
Connect the wire terminals to the spill switch and re secure
the bracket.
For aesthetics, the adaptor has been designed to accept a standard
matte black 7" appliance pipe and a decorative black band
(standard with the GS150KT). Both are available from your local authorized dealer / distributor.
W415-0098 / E / 06.28.10
2 FT MIN
10 FT TO
NEAREST
ROOFLINE
10 FT OR
MORE
FLAT ROOF
LESS THAN
10 FEET
2 FT
RIDGE
MIN
3 FT
MIN
3 FT
MIN
SPILL
SWITCH
3 FT
MIN
LESS THAN
10 FT
2 FT
MIN
WALL
59.1A
ADAPTER