7.0 ADJUSTMENTS

7.1

PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise
direction to reduce the gas fl ow.
Inlet pressure can be checked by turning screw (A) counter-
clockwise until loosened and then placing pressure gauge
tubing over the test point. Gauge should read 7" (minimum 4.5")
water column for natural gas or 13" (11" minimum) water column for
propane. Check that main burner is operating on "HI".
Outlet pressure can be checked the same as above using screw (B).
Gauge should read 3.5" water column for natural gas or 10" water column
for propane. Check that main burner is operating on "HI".
AFTER TAKING PRESSURE READINGS, TIGHTEN SCREWS
FIRMLY TO SEAL. DO NOT OVER TORQUE. LEAK TEST.
7.2

VENTURI ADJUSTMENT

This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame color to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
FRONT
BURNER
NG 1/4"
LP
1/4"
W415-0098 / E / 06.28.10
REAR
BURNER
1/2"
1/2"
PILOT
BURNER
THERMOCOUPLE
PILOT SCREW
39.3
VENTURI
BURNER
ORIFICE
49.1
AIR SHUTTERS
REAR BURNER
FRONT BURNER
THERMOPILE
B
A
AIR
SHUTTER
OPENING

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gds50pGs50nGs50p

Table of Contents