C. G eneral Operating Information
The P 5i s ESP control will maintain an output level to fit your temperature demands. There are two modes of
operation Stove Temp mode, where the control will maintain a specified constant temperature, regardless of
the surrounding environment temperature conditions, Or Room Temp mode, where the control will ad ust the
rate of burn to meet a specified room temperature setting. You also have the choice of Automatic or
ignition. Regardless of the mode selected, operation is controlled by both,
exhaust temperature- being reported by the ESP (Exhaust Sensing Probe),
and the microprocessor circuit board.
We ll discuss these control devices and their functions now.
1 . ESP (Ex haust Sensing Probe)
The ESP is a tiny thermistor located in the exhaust stream. The probe
changes it s thermal resistance based on minute changes in temperature,
which is monitored by the circuit board and used to determine the need for
changes in the burn rate to meet the temperature demand.
2 . Circuit Board
As stated previously, the circuit board is a microprocessor, which means it has
the ability to think and ad ust itself based on both, reported temperatures
and demand temperature. The circuit board will also flash a code sequence
on the Status light if an error is detected.
power light
Indicates power to the control.
status light
Will be lit in either stove or room temp
mode when pointer is not within off
position band except after normal shut
down. Blinks to indicate errors detected.
Indicates power to distribution blower.
Indicates power to combustion blower.
Indicates power to the feed motor.
Indicates power to the igniter.
Low Draft Adjustment Screw (see
page 26)
Temp dial
Allows you to adjust the room temperature in
Room Temp Mode using the outer scale marked
in degrees Fahrenheit. It also allows you to adjust
the stove temperature while in Stove Temp Mode
using the inner scale marked from 1 to 7.
2
P e l l e t s o r C o r n /P e l l e t M i x t u r e O n l y
dealer diagnostic port
For dealer maintenance
only. Requires special DDM
monitor supplied to Harman®
Dealers exclusively.
- 0-775R1
08 1
P3 5 i F ireplace Insert
ESP Location
feed adjuster
Sets the maximum feed rate.
Test
Runs all motors at full speed for one
minute to check operation. Afterwards
the combustion blower will remain on
low burn voltage.
igniter switch
Set to appropriate Start-Up mode.
mode selector
Allows you to choose between Room
Temp Mode, Stove Temp Mode, or
OFF. Also allows you to vary the
distribution blower speed by turning
the knob to the high or low side of
each mode.
Distribution Blower speed adjustment
range.
L = low
H = high
Variable speed anywhere between L
and H; although as the stove temp.
goes up , so does the low end of the
scale.
S a v e
T h e s e
I n s t r u c t i o n s

anual