Step 1 - Choose the Fan Site
Proper ceiling fan location and attachment to the building structure
are essential for safety, reliable operation, maximum efficiency, and
energy savings.
Choose a fan site where:
• No object can come in contact with the rotating fan blades
during normal operation.
• The fan blades are at least 7 feet above the floor and the ceiling is
at least 8 feet high.
• The fan blades have no obstructions to airflow, such as walls or
posts, within 30 inches of the fan blade tips.
• The fan is directly below a joist or support brace that will hold the
outlet box and the full weight of the fan.
Checklist for Existing Fan Site
If you want to use an existing fan site, complete the following checklist to
determine if the site is acceptable and safe for your new Hunter fan. If you
cannot check off every item, prepare a new fan site as described on this
page.
Fan Support System
Fan attaches directly to building structure.
Fan support system will hold full weight of the fan and light kit.
Ceiling Hole
The outlet box clearance hole is directly below the joist or support brace.
.
Outlet Box
The outlet box is an UL-approved octagonal 4" x 1-1/2" outlet box (or as
specified by the support brace manufacturer).
The outlet box is secured to the joist or support brace by wood screws
and washers through the inner holes of outlet box.
The outer holes of the outlet box are aligned with joist or support brace.
The bottom of the outlet box is recessed a minimum of 1/16" into ceiling.
Wiring
The electrical cable is secured to outlet box by an approved connector.
Six inches of lead wires extend from outlet box.
If your existing fan site is suitable, skip ahead to Section 2 • Installing the
Ceiling Plate.
1 • Getting Ready (continued)
).
3
42798-01 • 09/16/09 • Hunter Fan Company
30" From
Wall or
Nearest
Obstruction
7' Minimum
Blades to Floor
Suitable Existing Fan Site
Fan Support System
Fan Support
System
Wiring
8' Minimum
Ceiling Height
Outlet Box