Water Connections - Raypak 106 Installation & Operating Instructions Manual

Atmospheric above-ground pool & spa heater (chauffe-piscine)
Table of Contents

Advertisement

Pipe Sizing for Gas Connections
Model
Tubing
106
Cu
156
Cu
* Natural Gas 1000 BTU/FT
(Gaz Naturel 3154.5 W/m
* Propane Gas 2500 BTU/FT
(Le Gaz Propane 7886.3 W/m

Water Connections

The heater requires water flow and positive pressure
to fire and operate properly. It must therefore be
installed downstream of the discharge side of the filter
pump. A typical installation is plumbed as follows:
1. The inlet side of the filter is plumbed directly to the
discharge side of the filter pump;
2. The outlet side of the filter is then plumbed to the
inlet of the heater; and
3. The outlet of the heater is plumbed to the return
line to the pool or spa. The pump, filter and heater
are thus plumbed in series.
Plumbing from the heater back to the pool or spa must
not have any valves or restriction that could prevent
flow when the pump is operating.
Heater must be located so that any water leaks will not
damage the structure of adjacent area. PVC pipe may
be glued directly into supplied CPVC header unions.
Flow Rates
Model No.
Minimum
106/156
20 GPM (75 L)
*When flow rates exceed maximum 70 GPM, an external auxiliary
bypass valve is required. See External Auxiliary Bypass Valve sec-
tion for details.
Table H: Water Flow Rates
1/2 in. (1.27cm)
Input
NAT
105,000 BTU/hr
26 ft
(30.8 kW)
(8 m)
150,000 BTU/hr
13 ft
(43.9 kW)
(4 m)
3
0.60 Specific Gravity @ 0.5 in WC Pressure Drop
3
0.60 Densité @ 0.124 kPa Pressure Drop)
3
1.53 Specific Gravity @ 0.5 in WC Pressure Drop
3
1.53 Densité @ 0.124 kPa Pressure Drop)
Table G: Maximum Equivalent Pipe Length
Maximum
70 GPM (265 L)
3/4 in. (1.91cm)
LPG
NAT
65 ft
99 ft
(20 m)
(30 m)
34 ft
51 ft
(10 m)
(16 m)
Polymer Headers
Before attaching the supplied 2-inch (5 cm) CPVC
unions to the In/Out header, make sure the O-rings are
properly seated in the grooves. Use AquaLube or
equivalent non-petroleum-based lubricant on the O-
ring. Hand tighten the unions. Glue PVC or CPVC
piping directly to the unions.
Drain Plug
Fig. 10: In/Out Header for 2" Installation
Fig. 11: Optional In/Out Header for 1-1/2" (3.8 cm)
or 1-1/4" (3.2 cm) Hose Connection
14
1 in. (2.54cm)
LPG
NAT
252 ft
350 ft
892 ft
(77 m)
(107 m)
(272 m)
130 ft
180 ft
459 ft
(40 m)
(55 m)
(140 m)
In/Out Header
O-Ring
Tail Piece
In/Out Header
Hose Connector
LPG
Nut
2" Pipe
(5cm)
Hose