Gas Pressure Regulator - Raypak 106 Installation & Operating Instructions Manual

Atmospheric above-ground pool & spa heater (chauffe-piscine)
Table of Contents

Advertisement

Fig. 7: Gas Line Sediment Trap
NOTE: Do not use Teflon tape on gas line pipe
thread. A flexible pipe sealant suitable for LP gases
is recommended.

Gas Pressure Regulator

The gas pressure regulator is preset at 4.0 in W.C.
(1.0kPa) for natural gas and 10.0 in W.C. (2.5kPa) for
propane gas.
If adjustment is needed, remove plug and turn adjust-
ment screw clockwise to increase pressure or
counter-clockwise to decrease pressure.
Gas Pressure*
Natural Gas
Max. Inlet
10.5 in. WC
(static)
(2.6 kPa)
Min. Inlet
5 in. WC
(dynamic)
(1.2 kPa)
Manifold Gas
4 in. WC
(dynamic)
(1.0 kPa)
*Static means without heater operating, dynamic refers to heater
operating.
Table F: Gas Pressure
Gas Pressure Adjustment Locations
Electronic Ignition Gas Valves
Propane Gas
13 in. WC
(3.2 kPa)
11 in. WC
(2.7 kPa)
10 in. WC
(2.5 kPa)
13
Fig. 8: Honeywell Gas Valve
Fig. 9: Location of Gas Pressure Adjustment

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

156

Table of Contents