Section 8: Vent Information; Venting Termination Requirements - Quadra-Fire Edge60 Owner's Manual

Zero clearance pellet fireplace nutural/curved/tuscan/studio
Table of Contents

Advertisement

R
R R
8
Vent Information
A. Venting Termination Minimum Requirements
O
Figure 37.1
An Outside Air Kit is required on all installations.
1 in.
Above Finish Grade (the grade surface
A
must be a non-combustible material
1 in.
Open door or window: below or to the side
B
1 in.
Open door or window: above
B
6 in.
Permanently closed window: above, below
C
or to the side
18 in.
Vertical clearance to a ventilated soffit
D
located above the terminal within a hori-
zontal distance of  ft from the center-line
of the terminal
1 in.
Clearance to unventilated soffit
E
1 in.
Clearance to outside corner
F
1 in.
Clearance to inside corner
G
6 in.
Above gas meter/regulator measured from
H
horizontal center-line of regulator
6 in. USA
Clearance to service regulator vent outlet
I
7 in. Canada
1 in.
Clearance to non-mechanical air supply
J
inlet to the building or the combustion air
inlet to any other appliance
10 ft horizontal
Clearance to mechanical air supply
K
 ft vertical
7 ft.
Above paved sidewalk, paved driveway
L
located on public property
1 in.
Under an open veranda, porch, deck or
M
balcony
See Note
Electric service: above, below or to the
N
below*
side (location must not obstruct or interfere
with access)
4 in.
Adjacent building, fences and protruding
O
parts of the structure
1 in.
Clearance above roof line for vertical
P
terminations
*NOTE: Consult local building, fire officials or authorities having
jurisdiction. Local codes or regulations may require different
clearances.
April 9, 2009
D
E
L
C
B
V
FIXED
CLOSED
OPEN
F
V
B
V
Termination Cap
Inside Corner
G
V
A
H
FIXED
OPEN
V
CLOSED
B
V
A
B
G
Air Supply Inlet
Gas Meter
X
Outside Air Kit must be ordered separately.
4 in.
Above grass, top of plants, wood or any other com-
bustible
1 in.
Clearance from any forced air intake of other appli-
ance
1 in.
Clearance horizontally from combustible wall
15 in.
Vented directly through a wall, minimum length of
horizontal pipe
1 in. horizontal
Minimum horizontal or vertical terminations must
1 in. vertical
protrude from wall
NOTICE:
Do NOT Terminate Vent:
• In any location that will allow flue gases or soot to enter
or stain the building.
• In any location which could create a nuisance or hazard.
• In any enclosed or semi-enclosed area such as a carport,
garage, attic, crawl space, under a sun deck or porch,
narrow walkway.
• Closely fenced area, or any location that can build up
a concentration of fumes such as a stairwell, covered
breezeway, etc.
NOTICE:
Termination must exhaust above air inlet elevation.
It is recommended that at least 60 inches (154mm) of
vertical pipe be installed when appliance is vented directly
through a wall. This will create a natural draft, which will
help prevent the possibility of smoke or odor venting into
the home during a power outage.
It will also keep exhaust from causing a nuisance or hazard
by exposing people or shrubs to high temperatures.
The safest and preferred venting method is to extend the
vent vertically through the roof or above the roof.
7051-158
EDGE 60 Pellet Fireplace
V
N
N
N
Electrical
V
V
Service
N
V
P
G
M
I
X
V
J or K
Restricted Area
Page 7