Using the Calibration Application
3-6
3. Click Start Printer Calibration.
4. Place X-Rite i1PRO Device in its base to calibrate the device.
Make sure that it is fully seated in the base.
5. Click and release the button on the device to calibrate it.
Once the X-Rite i1PRO Device is calibrated, the printer prints a
calibration target.
6. Secure the calibration target into the tray clip of the X-RITE
i1PRO scanning tray.
7. Align the scanning guide over the first row of patches on the
target.
8. Place the X-RITE i1PRO Device on the scanning guide.
9. Position the X-RITE i1PRO Device in the white area next to the
first row of patches on the target strip.
10. Click and hold the button. Wait for the device to beep.
NOTE: If your computer does not have a sound card and/or
speakers, there will not be an audible beep. Wait for the
light below the reading probe of the X-RITE i1PRO device
to illuminate. Wait an additional 3 seconds for the lamp to
stabilize before you start to scan.
11. Continue to hold the button and slowly move the X-RITE
i1PRO Device completely across the patches on the target and
into the white area at the end of the row of patches.
12. Release the button.