Installing The Memory Fan (Celsius R); Removing The Heat Sink With Fan (Celsius R) - Fujitsu CELSIUS M4 Series Operating Manual

Table of Contents

Advertisement

Installing the memory fan (CELSIUS R)

Insert the memory fan into the holding plate (1). Make sure that you feel the memory fan
engage.
Connect the memory fan cables on the mainboard (see the manual for the mainboard).
Install the cross-piece (see "Installing the cross-piece").
Install the side fan (see "Installing the side fan").
Close the casing (see "Closing the casing").

Removing the heat sink with fan (CELSIUS R)

In order to change the processor, you must remove the heat sink. There is an additional fan secured
at the rear of the heat sink and you must also remove it.
If there is another heat sink present, remove this too in the manner described below.
i
Open the casing (see "Opening the casing").
Remove the side fan (see "Removing the side fan").
Remove the cross-piece (see "Removing the cross-piece").
If present, remove the fan duct on the front processor by pressing the locking lugs to the side
and taking out the fan duct.
A26361-K994-Z220-1-7619, Edition 2
1
System upgrades
49