4. Set up

Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
Power Supply: Before plugging your unit in, be sure the source voltage in your area matches the
required voltage. The Light is available in a 110v to 250v version. Because line voltage may vary from
venue to venue, you should be sure your unit voltage matches the wall outlet voltage before
attempting to operate you fixture.

4.1. Fuse replacement

With a flat head screwdriver wedge the fuse hold out of its housing. Remove the damaged fuse from
its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect
power.

4.2. Fixture linking

You will need a serial data link to run light show of one or more fixtures using a DMX-512 controller or
to run synchronized on two or more fixtures set to a master/slave operating mode. The combined
number of channels required by all the fixtures on a serial data link determines the number of fixtures
the data link can support.
Maximum recommended serial data link distance: 500 meters (1640ft).
Maximum recommended number of fixtures on a serial data link: 32 fixtures.
Data cabling
To link fixtures together you must obtain data cables. If you choose to create your own cable please
use data-grade cables that can carry a high quality signal and are less prone to electromagnetic
interference.

4.3. 3-Pin to 5-Pin conversion chart

Note! If you use a controller with a 5 pin DMX output connector. you will need to use a 5pin to 3 pin
CHAUVET Model No: DMX 5M or DMX 5F
The chart below details a proper cable conversion: