RF WIRING DIAGRAM

BLOWER
BATTERY
BACK-UP
120V EXTENSION
LIGHT
TRANSFORMER
MODULE
(OPTIONAL)
ON/OFF
BROWN
SWITCH
WHITE
GREEN
GAS CONTROL
ORANGE
VALVE
Stepper
PILOT
Motor
FAN
MAIN
(GND)
PILOT
ELECTRONIC
WHITE
CONTROL MODULE
ORANGE
JUNCTION BOX
NOTICE: For "RF" Fireplace models with Premium Multi-Function Remote Control, Refer to the separate instructions for operation of the
remote control system.