Installation - Empire Comfort Systems DLCX36SP93N-1 Installation Instructions And Owner's Manual

Direct vent gas fireplace heater
Hide thumbs Also See for DLCX36SP93N-1:
Table of Contents

Advertisement

Attention: If the appliance is installed directly on carpeting, tile
or other combustible material other than wood flooring, it shall be
installed on a metal or wood panel extending the full width and depth
of the appliance. The vertical dimension must be adjusted when a
metal or wood panel is placed beneath the appliance.
Finishing (Figures 11 and 12)
Finish the walls with the material of your choice.
Warning: When finishing the fireplace never obstruct
or modify the air inlet/outlet openings in any manner.
provide adequate clearances around air openings into the
combustion chamber.
Caution: If the joints between the finished wall and the fireplace
surround (top and sides) are sealed, a 300°F minimum sealant
material must be used. These joints are not required to be sealed.
Only non-combustible material (using 300°F minimum adhesive if
needed), can be applied directly above the fireplace cabinet. See
Figure 11.
FINISHED WALL
(MUST BE FLUSH WITH THE
FACE OF TH FIREPLACE)
6 1/4" (158.75mm) OF
NON-COMBUSTIBLE MATERIAL
JOINT BETWEEN FINISHED
WALL AND UNIT CAN BE SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
Note: Fireplace shown with finish wall surfaces. A surround kit must
be installed to complete installation.
Page 16

INSTALLATION

2 X 4 HEADER
STANDOFF
6 ½"
PERPENDICULAR SIDEWALL
CLEARANCE NEEDED FOR
INSTALLATION OF SURROUND
KITS.
3" MINIMUM REQUIRED FOR
SURROUND INSTALLATION.
Figure 11
vERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL
90 ELBOW
°
NOTE: 1 FOOT SECTION (MIN.)
OF VERTICAL VENT REQUIRED
WHEN USING HORIZONTAL
TERMINATION OFF TOP.
WALL FIRESTOP / THIMBLE
"A"
"B"
6"
21 1/4" to 22 3/4"
(540 mm to 578 mm)
9"
24 1/4" to 25 3/4"
(616 mm to 654 mm)
12"
27 1/4" to 28 3/4"
(692 mm to 730 mm)
Figure 12
"B"
"C"
16 1/2"
MIN
"A" PIPE LENGTH
4" MIN
VENT CAP
9" (229 MM)
MINIMUM
"C"
4 3/4" to 6 1/4"
(121 mm to 159 mm)
7 3/4" to 9 1/4"
(197 mm to 235 mm)
10 3/4" to 12 1/4"
(273 mm to 311 mm)
29004-0-0711

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dlcx36sp93p-1

Table of Contents