vENTING FIREpLACE - TOp (continued)
SEE VENT CHART
FOR PERMISSIBLE
"H" AND "V"
DIMENSIONS
1 FOOT VERTICAL
PIPE REQUIRED
A
CENTER OF ELBOW
STRAIGHT OUT
(MINIMUM)
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH
THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE
ELBOW AND 1 FOOT VERTICAL VENT OFF TOP OF
FIREPLACE
FIREpLACE
HARD ELBOW DIMENSIONS
SERIES
"A"
DLCX36Sp
53"
(1346.2mm)
positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two (2) studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Cutting the Hole (Figure 19)
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This hole
must be 11" (279.4 mm) high x 10" (254mm) wide with its center
line determined by the amount of vertical rise and horizontal run of
the termination. See Figure 19.
When locating the hole it must be noted that the bottom of the cap
must be 12" (305mm) above the ground level, and top of the cap
must be no less than 18" (457mm) below a combustible projection,
and no closer than 9" (229mm) to any wall running parallel to vent
termination. See Figures 32, 33, and 36.
Page 20
10"
(254mm)
11"
(279mm)
H
C
B
Figure 19
"B"
"C"
4 1/2"
6 1/2"
(114.3mm)
(165.1mm)
C
B
V
NOTE: 1 FOOT SECTION (MIN.)
OF VERTICAL VENT REQUIRED
WHEN USING HORIZONTAL
TERMINATION OFF TOP.
MAXIMUM HORIZONTAL
RUN WITH 1 FOOT VERTICAL
RISE AND 90° ELBOW
MAXIMUM HORIZONTAL
RUN WITH MINIMUM
VERTICAL RISE AND
90° ELBOW
8' (244cm)
TO BOTTOM
OF UNIT
4" MIN
90 ELBOW
°
WALL FIRESTOP / THIMBLE
Figure 20
(1219mm)
20' (6.1m)
PIPE STRAPS
EVERY 3' (91cm)
Figure 21
VENT CAP
9" (229 MM)
MINIMUM
4' MAX.
29004-0-0711