Empire Comfort Systems DVD32FP34N-1 Installation Instructions And Owner's Manual page 13

Direct vent gas fireplace heater
Table of Contents

Advertisement

HORIzONTAL ONLY, STRAIGHT OUT THE bACK
"
A"
PIPE LENGTH
"A"
6"
5 1/8" to 6 1/2"
9"
8 1/8" to 9 1/2"
12" 11 1/8" to 12 1/2"
vERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
"A"
"B"
6"
11 1/4" to 12 3/4"
9"
14 1/4" to 15 3/4"
12"
17 1/4" to 18 3/4"
26988-3-1012
INSTALLATION (continued)
VENT CAP
WALL FIRESTOP/
THIMBLE
"B"
Figure 15
WALL FIRESTOP/
THIMBLE
"C"
4 3/4" to 6 1/4"
7 3/4" to 9 1/4"
10 3/4" to 12 1/4"
Figure 16
CORNER INSTALLATION vERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
Dim.
ADVD32
36 1/8"
A
918 mm
25 1/2"
B
648 mm
11 1/2"
C
292 mm
51 1/8"
D
1.299 m
Figure 17
CORNER INSTALLATION HORIZONTAL, 45° ELBOW TO
HORIZONTAL OUT THE WALL
WALL FIRESTOP/
THIMBLE
ADVD32
"A"
"B"
6"
4" to 5 1/2"
9"
6" to 7 1/2"
12"
9" to 10 1/2"
Figure 18
WALL FIRESTOP/
THIMBLE
VENT
CAP
ADVD36
38 3/8"
975 mm
27 1/8"
689 mm
12 5/8"
321 mm
54 1/4"
1.378 m
ADVD36
"B"
4" to 5"
6" to 7 1/2"
9" to 10 1/2"
Page 13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvd36fp34n-1

Table of Contents