Pegasus F2 N 2S
From natural to liquid gas
1 Replace the nozzles at the main burner and pilot light, inserting the nozzles specifi ed in the
technical data table in chap. 4.3.
2 Remove the small plug 3 (Fig. 14) from the gas valve, screw the ignition "STEP" regulator 2, contained
in the conversion kit, onto the valve and put the plug 3 back onto the regulator.
3 Adjust the burner gas pressures, for minimum and maximum power as described in the above
paragraph, setting the values given in the technical data chart in paragraph 4.3.
4 For model 102, equipped with 2 gas valves, steps 2 and 3 must be carried out on both valves.
5 Apply the sticker, contained in the conversion kit, near the dataplate as proof of the conversion.
From liquid to natural gas
Carry out the same operations explained above, taking care to remove the ignition "STEP" regulator 2
(Fig. 14) of the gas valve; the plug 3 (Fig. 14) must be fi tted straight onto the valve.