Pegasus F2 N 2S
Characteristics of the system water
In the presence of water harder than 25° - 30° Fr, we recommend the use of suitably conditioned
water for the heating system in order to avoid possible scaling in the boiler, caused by hard water,
or corrosion produced by aggressive water. It should be remembered that, because of its low
thermal conductivity, even scaling of just a few mm thick causes signifi cant overheating of the boiler
walls with consequent serious problems.
Water treatment is indispensable for the heating system in the following cases:
A)very large systems (containing large amounts of water):
B) frequent introduction of replenishing water in the system, in the case of draining the
system either partially or totally.
Positioning the module generators and connecting the fl ues to the manifold
The set of module generators can comprise at most 4 units; depending on controller requirements they
can be arranged with the modules either facing each other or in a line.
Position the generators and connect the fume extraction pipes according to the diagrams and data
given in the charts of Fig. 8 - 9. Seal the various pipe joints.
HEAT GENERATORS WITH FACING MODULES COMPREHENSIVE OF FUME DUCTING CHAMBER
SIDE VIEW
100
STANDARD BOILER
PEGASUS F2 N 51 2S
PEGASUS F2 N 68 2S
PEGASUS F2 N 85 2S
fi g. 8
PEGASUS F2 N 102 2S
HEAT GENERATORS WITH MODULES IN LINE COMPREHENSIVE OF FUME MANIFOLD
CALDAIA BASE
PEGASUS F2 N 51 2S
PEGASUS F2 N 68 2S
PEGASUS F2 N 85 2S
PEGASUS F2 N 102 2S
fi g. 9
PLAN VIEW 2 MODULES
1900
100
Ø
Heating
Output
power
L
H
Ø
kW
kW
102
112,0
550
1700
250
136
149,6
640
1700
250
170
187,0
720
1725
300
204
224,0
800
1725
300
2 MODULES
100
L
Heating
Output
L
H
power
kW
kW
102
112,0
1200
1690
250
136
149,6
1380
1690
250
170
187,0
1540
1715
300
204
224,0
1700
1715
300
PLAN VIEW 3 MODULES
1900
100
Heating
Output
power
L
H
kW
kW
153
168,0
1200
1725
204
224,4
1380
1725
255
280,5
1540
1750
306
336,0
1700
1750
3 MODULES
100
100
L
Heating
Output
Ø
L
H
power
kW
kW
153
168,0
1850
1715
204
224,4
2120
1715
255
280,5
2360
1740
306
336,0
2600
1740
PLAN VIEW 4 MODULES
1900
100
Heating
Output
Ø
power
L
H
kW
kW
300
204
224,0
1200
1750
300
272
299,2
1380
1750
350
340
374,0
1540
1775
350
408
448,0
1700
1755
4 MODULE
100
100
100
L
Heating
Output
Ø
L
H
power
kW
kW
300
204
224,0
2500
1740
300
272
299,2
2860
1740
350
340
374,0
3180
1765
350
408
448,0
3500
1765
Ø
350
350
400
400
Ø
350
350
400
400