Comtech EF Data CDM-600L Installation And Operation Manual page 76

Open network satellite modem (2.4 kbps – 20 mbps)
Hide thumbs Also See for CDM-600L:
Table of Contents

Advertisement

CDM-600L Satellite Modem
Front Panel Operation
For units with Firmware Version 1.3.0 or greater: ESC++ is available as standard. If
enabled, the lower of the Tx or Rx primary data rate limits that maximum ESC baud rate,
according to the table below. Both Tx and Rx framing must be set to ESC++. See Chapter
13 for more details on the framing used.
Data rate
>64 kbps
>= 128 kbps
>= 192 kbps
>= 256 kbps
>= 384 kbps
>= 512 kbps
6.3.1.10
CONFIG: REMOTE CONTROL
REMOTE CONTROL = LOCAL
Select LOCAL or REMOTE using the [↑] [↓] arrow keys, then press ENTER.
CONFIG: REMOTE CONTROL: INTERFACE
INTERFACE= RS-485-4W
Use the [←] [→] arrow keys to select the parameter to edit: Interface, Address or
Baudrate.
Edit the Interface type, Baudrate and each digit of the Address using the [↑] [↓] arrow
keys.
Max ESC++ baud rate
4800
9600
14400
19200
28800
38400
If LOCAL is selected, the REMOTE CONTROL is disabled. Remote monitoring
is still possible.
If REMOTE is selected, then the following sub-menus will be displayed.
ADDRESS= 0001
For RS-485, the permitted address range is 1 to 9999.
Address 0 is reserved for universal addressing.
For RS-232, the Address is fixed at 0000.
(LOCAL,REMOTE)
(232,485-2,485-4)
BAUDRATE= 9600
6–24
Revision 2
MN/CDM600L.IOM

Advertisement

Table of Contents
loading

Table of Contents