5. R.V. coil control <MUH-A07/A09/A12WV>
Heating · · · · · ON
Cooling · · · · · OFF
Dry · · · · · · · · OFF
When operation starts, the 4-way valve reverses for 5 seconds right before start-up of the compressor.
Operation time chart
Compressor
R.V. coil
Outdoor fan
11-5. "I FEEL CONTROL" (
(1) Press OPERATE/STOP(ON/OFF) button.
OPERATION INDICATOR lamp of the indoor unit turns on
with a beep tone.
(2) Select "I FEEL CONTROL"(
TION SELECT button.
(3) The operation mode is determined by the initial room tem-
perature at start-up of the operation, as shown on the
right table.
Once the mode is fixed, the mode does not change by room temperature afterwards.
Under the ON-TIMER (
tion starts.
When the system is stopped on the remote controller and restarted within 2 hours in "I FEEL CONTROL" (
the system operates in previous mode automatically regardless of the room temperature.
Operation time chart
When the system is restarted after 2 hours and more, the operation mode is determined by the room temperature at
start-up of the operation.
Operation time chart
(COOL/DRY)
5 sec.
ON
OFF
ON
OFF
ON
OFF
) OPERATION
) mode with the OPERA-
) operation, mode is determined according to the room temperature at set time the opera-
Example
Previous operation
COOL mode of
"I FEEL CONTROL"
or COOL mode
Example
Previous operation
COOL mode of
"I FEEL CONTROL"
or COOL mode
(HEAT)
5 sec.
Initial room temperature
MU&MUX type
MUH type
25: or more
25: or more
more than13:,
23:or more,
less than 25:
less than 25:
less than 23:
Restart
COOL mode of
"I FEEL CONTROL"
Restart
COOL or DRY or
HEAT mode of "I FEEL
CONTROL" that deter-
mined by room tem-
perature at start-up of
the operation.
89
ON
OFF
ON
OFF
ON
OFF
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
) mode,