Disassembly Instructions Mux-A10Wv - - Mitsubishi Electric MSC-A07WV Service Manual

Split-type, air conditioners split-type, heat pump air conditioners
Hide thumbs Also See for MSC-A07WV:
Table of Contents

Advertisement

14-4. MUX-A10WV -
OUTDOOR UNIT
OPERATING PROCEDURE
1. Removing the cabinet
(1) Remove the screws of the top panel.
(2) Remove the screw of the service panel.
(3) Remove the screws of the cabinet.
(4) Remove the screws of the front panel and motor support.
(5) Remove the service panel, and remove the screw from
the insides.
(6) Remove the top panel.
(7) Remove the cabinet.
Photo 3
Fuse (F61)
Relay panel
Outdoor fan
Screw of fixing
capacitor
relay panel
Terminal block
(TB3)
2. Removing the relay panel
(1) Remove the service panel and the cabinet.(Refer to 1.)
(2) Remove the following connectors.
• Outdoor fan motor
• Solenoid coil (21R, 21R1, 21R2)
E1
Compressor
Fuse (F62)
capacitor (C1)
Relay
Contactor (52C)
(C2)
(o1)
Relay
(o2)
Photo 1
Set screws of the front panel
and motor support
Screws
of the
cabinet
Terminal
block
Photo 2
(TB1)
Terminal
block
(TB2)
Screws
of fixing
relay
panel
Surge
Screws
absorber
of the
(DSAR)
cabinet
Photo 4
Propeller
fan
Propeller
fan nut
135
PHOTOS
Screws of the top panel
Set screws of
Hook
the outdoor
fan motor
Lead wire
Outdoor
Outdoor
fan motor
fan motor
connector
Screws
of the
top
panel
Screws
of the
service
panel
Lead
clamp
Solenoid coil
connector
(21R, 21R1,
21R2)

Hide quick links: