Mitsubishi Electric MSC-A07WV Service Manual page 139

Split-type, air conditioners split-type, heat pump air conditioners
Hide thumbs Also See for MSC-A07WV:
Table of Contents

Advertisement

OPERATING PROCEDURE
5. Removing the compressor (A, B)
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover on the compressor.
(5) Disconnect lead wires from the compressor.
(6) Recover gas from the refrigerant circuit.
(7) Disconnect the welded part of the discharge pipe.
(8) Disconnect the welded part of the suction pipe.
(9) Remove nuts fixing the compressor.
( 10 ) Remove the compressor.
NOTE
Before using a burner, reclaim gas from the pipes until the
pressure gauge shows 0 kg/cm
Use the burner under the condition that gas can be recovered
even when the inner pressure rises by heat.
6. Removing the compressor (C)
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel. (Refer to 2.)
(3) Remove the screws fixing back panel.
(4) Remove the back panel.
(5) Remove the soundproof felt.
(6) Remove the terminal cover on the compressor.
(7) Disconnect lead wires from the compressor.
(8) Recover gas from the refrigerant circuit.
(9) Disconnect the welded part of the discharge pipe.
( 10 ) Disconnect the welded part of the suction pipe.
( 11 ) Remove nuts fixing the compressor.
( 12 ) Remove the compressor.
NOTE
Before using a burner, reclaim gas from the pipes until the
pressure gauge shows 0 kg/cm
Use the burner under the condition that gas can be recovered
even when the inner pressure rises by heat.
2
(0 MPa) .
2
(0 MPa) .
Photo 5
Suction pipe
Discharge pipe
Sound proof felt
139
PHOTOS
Terminal cover
Terminal cover