Outdoor Unit Functional Parts And Electrical Parts - Mxz-A18Wv - - Mitsubishi Electric MSC-A07WV Service Manual

Split-type, air conditioners split-type, heat pump air conditioners
Hide thumbs Also See for MSC-A07WV:
Table of Contents

Advertisement

MXZ-A18WV -
E1
15-14. OUTDOOR UNIT
FUNCTIONAL PARTS AND ELECTRICAL PARTS
1
2
15-14. OUTDOOR UNIT FUNCTIONAL PARTS AND ELECTRICAL PARTS
Part numbers that are circled are not shown in the illustration.
No.
Parts No.
1
E02 735 337
REACTOR
2
E02 735 444
NOISE FILTER P.C. BOARD
3
E02 735 374
TERMINAL BLOCK
4
E02 573 375
TERMINAL BLOCK
5
E02 735 241
FUSE HOLDER
6
E02 735 382
FUSE
7
E02 735 306
GAS PIPE TEMPERATURE THERMISTOR SET
8
E02 735 308
THERMISTOR SET
9
ELECTRONIC CONTROL P.C. BOARD
E02 735 450
10
E02 735 309
FIN TEMPERATURE THERMISTOR
11
E02 735 385
FUSE&VARISTOR
15-15. ACCESSORY
12
E02 444 704
DRAIN SOCKET
13
E02 444 705
DRAIN CAP
9
3
4
Parts Name
15-15. ACCESSORY
7
8
5
6
Symbol
Q'ty / unit
in Wiring
MXZ-A18WV-
Diagram
L
TB2
TB1
F61
RT6A, RT6B
RT61,RT62,RT63,RT68
RT65
F912,NR63
155
12
13
Remarks
E1
1
1
1
1
1
1
20A/ 250VAC
1
1
1
1
1
3.15A 250V
1
2
2PCS/SET