Installing Line For Gas Logs - Vermont Castings ODSR36A Installation And Operating Manual

Odsr series "a" outdoor woodburning fireplace
Table of Contents

Advertisement

ODSR Series "A" Outdoor Woodburning Fireplace

Installing Line for gas Logs

Vermont Castings Group fireplaces are designed to ac-
cept a 1/2" (13 mm) gas line for installation of an approved
gas appliance. (Vermont Castings Group manufactures a
wide variety of gas logs for use in Vermont Castings Group
Fireplaces.)
Be sure to have the appliance installed in accordance with
building codes.
Gas connection may enter from either left or right side of
the fireplace.
Locate appropriate gas line in the outer casing of fireplace
and remove insulation from gas line tube. (Fig. 27)
From inside the fireplace, locate the knockout on the fire-
brick -- be sure you are on the appropriate or "gas line" side
of the fireplace. Using a flat bladed screwdriver or small
chisel and hammer, carefully tap around the knockout until
it loosens and falls out.
Install 1/2" (13 mm) certified gas pipe through opening.
After gas pipe installation is complete, use insulation that
was removed from gas line tube to repack space around
the pipe. Material should be inserted from outside of the
fireplace and packed tightly to totally seal between the
pipe and tube.
NOTE: gas pipe should not come in contact with any
wood structures until it has reached a point at least
one (1) inch away from fireplace side.
NOTE: When installing an ANSI Z21.11.2 ventless appli-
ance the finishing material used for the mantel must be
rated at 250°F or greater.
BTU input of a gas appliance installed in fireplace should
be rated less than 100,000 BTU/Hr.
Gas pipe installation is intended for connection to a deco-
rative gas appliance only when (1.) incorporating an auto-
matic shutoff device and (2.) complying with the Standard
for Decorative Gas Appliances for Installation in Vented
Fireplaces (ANSI Z21.60) or Gas-Fired Log Lighters for
Woodburning Fireplaces.
Decorative gas appliance should be installed in accordance
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54
(latest edition).
If installing an unvented gas log set, refer to statement below:
18
Only unvented gas logsets which have been found to comply
with the Standard for Unvented Room Heaters, ANSI Z21.11.2,
are to be installed in this fireplace.
Hole in Outer Casing
Gas Line
Tube
Ceramic
Knockout
Hole in
Casing
Fig. 27 Gas line access.
CAUTION: WhEN USINg DECORATIVE gAS
APPLIANCE, FLUE DAMPER MUST BE SET
IN FULLY OPEN POSITION. IF YOU hAVE
gLASS DOORS ON ThE FIREPLACE, ThEY
MUST ALSO BE FULLY OPENED.
WARNINg: DO NOT OPERATE AN UNVENTED
gAS LOg SET IN ThIS FIREPLACE WITh ThE
ChIMNEY REMOVED.
WARNINg: WhEN INSTALLINg AN UNVENTED
AS LOg SET, ThE Vermont Castings group
MODEL CABL OR CABR 4" ADJUSTABLE
hOOD MUST BE USED.
Fireplace Top View
1"
Min.
Supply Line
Repack Insula-
tion
1/2"
Ceramic
Knockout
(Both sides)
FP560
FP560
BR/BC
11/10/97
20006811