Standard Ceiling With A Factory Built Chimney; Cathedral Ceiling With A Factory Built Chimney - Lopi Liberty Owner's Manual

Wood stove
Hide thumbs Also See for Liberty:
Table of Contents

Advertisement

S
TOVE
P
12
AGE
S
TANDARD
C
EILING WITH
F
A
ACTORY
B
UILT
C
HIMNEY
C
ATHEDRAL
C
EILING WITH
F
A
ACTORY
B
UILT
C
HIMNEY
I
NSTALLATION
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Insulation
Follow the chimney
manufacturer's instructions
and clearances for floor
penetrations. A chimney
support is required, an attic
insulation shield is required
where insulation is present.
Chimney Connector Sections
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions - usually 2")
Chimney Connector Sections
Floor Protection
(See the section "Floor
Protection Requirements"
for more details)
(C
.)
ONT
}
}
}
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm
collar and flashing are
required (some require a
radiation shield).
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions - usually 2")
Minimum 15'
Maximum 33'
Stove Clearances
(See the section "Stove
Placement Requirements"
for more details)
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm
collar, flashing, and
cathedral-style chimney
support are required (some
require a radiation shield).
Minimum 15'
Maximum 33'
Stove Clearances
(See the section "Stove
Placement Requirements"
for more details)