Stove Placement Requirements; Floor Protection Requirements - Lopi Liberty Owner's Manual

Wood stove
Hide thumbs Also See for Liberty:
Table of Contents

Advertisement

S
P
TOVE
LACEMENT
HINT: REDUCING CLEARANCES - Clearances may be reduced by methods specified in
¥
Stove must be placed so that no combustibles are within, or can swing within (e.g. drapes,
doors), 36" of the front of the stove
¥
If the stove is placed in a location where the ceiling height is less than 7', it must follow the
requirements in the section "Alcove Installation Requirements"
¥
Must maintain the following clearances to combustibles (drywall, furniture, etc.):
* Reduced clearance installations require one of the chimney systems listed below:
¥ DURAVENT model DVL with DURA-PLUS chimney
¥ SECURITY model DP with SECURITY model ASHT or S2100 chimney
¥ Metalfab model DW connector with TG chimney
NOTE:
Reduced clearance connectors can not connect directly to the flue collar. Make sure to order
an appliance adapter for the brand of connector being used.
F
P
LOOR
ROTECTION
¥
Must be non-combustible and at least
.018" thick (26 gauge)
¥
Must extend 6" to the side and rear of
the appliance
¥
Must extend 16" from the front
(measure from the faceplate)
¥
Minimum 42 3/8" deep by 39 1/2"
wide
R
EQUIREMENTS
NFPA 211, listed wall shields, pipe shields, or other means approved by local
building or fire officials.
Minimum Clearance
(See the illustration below)
A
Sidewall to stove
B
Backwall to stove
C
Cornerwall to stove
D
Connector to sidewall
E
Connector to backwall
F
Connector to cornerwall
b
a
d
Measure all clearances from the
nearest edge of the stove top.
R
EQUIREMENTS
S
I
TOVE
NSTALLATION
Singlewall
Connector
16"
15"
9 1/2"
28"
18 1/4"
21"
Rear
heat
e
shield
c
¥ AMERI-TEC model DCC with model HS chimney
¥ Standard Masonry Chimney with any one of the above listed connectors
6" Minimum
(from rear of stove, not stove top or heat shield)
16" Minimum
(from faceplate)
(C
ONT
Reduced
Clearance*
16"
10"
7 1/2"
27 1/2"
12 3/4"
18 1/2"
c
f
Heat Shield
Stove Top
6" Minimum
(from side of stove,
not stove top)
Floor Protection
(Minimum .018" thick)
.)
P
7
AGE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Endeavor

Table of Contents