8.2 Stepping motors error messages
Error number
Error 2101
Error 2103
Error 2152
Error 2153
Error 2156
Error 2201
Error 2253
Error 2256
Error 2353
Error 2356
Error 2401
Error 2501
Error 2601

8.3 Operating indicator error messages

Error number
Error 3100
Error 3101
Error 3102
Error 3103
Error 3107
Meaning
Step motor feed clamp timeout reference
- Faulty cable to the reference switch
- Faulty reference switch
Step motor feed clamp has step loss
Step motor feed clamp excess
current
Step motor feed clamp excess voltage
- Too high mains voltage
Step motor feed clamp overheat
- Step motor feed clamp seized up
- Faulty step motor feed clamp
- Faulty control
Step motor corner-blade frames
timeout reference
- Faulty cable to the reference switch
- Faulty reference switch
Step motor corner-blade frames
excess voltage
- Too high mains voltage
Step motor corner-blade frames overheat
- Step motor corner-blade frames
seized up
- Faulty step motor corner-blade frames
- Faulty control
Step motor tape feeder excess voltage
- Too high mains voltage
Step motor tape feeder overheat
- Step motor tape feeder seized up
- Faulty step motor tape feeder
- Faulty control
- Failure step motor seam-start
corner-blade
- Failure step motor seam-end
corner-blade
- Failure step motor piping cutter
Meaning
Machine Control Voltage
- Temporary mains voltage drop
Machine Power Voltage
- Temporary mains voltage drop
Machine Voltage Sewing Motor
- Temporary mains voltage drop
Machine Voltage Step Motors
- Temporary mains voltage drop
Machine Temperature
- Vent holes closed
- Ventilation grid soiled
Remedy
- Replace cable
- Replace reference switch
- Check seizing of the feed clamp
- Replace step motor feed clamp
- Replace control
Check the mains voltage
- Eliminate seizing
- Replace step motor feed clamp
- Replace control
- Replace cable
- Replace reference switch
Check the mains voltage
- Eliminate seizing
- Replace step motor corner-blade frames
- Replace control
Check the mains voltage
- Eliminate seizing
- Replace step motor tape feeder
- Replace control
Faulty cable to the reference switch
Faulty reference switch
Faulty step motor, seized up.
Faulty cable to the reference switch
Faulty reference switch
Faulty step motor, seized up.
Faulty cable to the reference switch
Faulty reference switch
Faulty step motor, seized up.
Remedy
- Check the mains voltage
- Check the mains voltage
- Check the mains voltage
- Check the mains voltage
- Check the vent holes
- Clean the ventilation grid