2-3 PERIODIC MAINTENANCE AND TUNE-UP PROCEDURES

MAINTENANCE PROCEDURES

This section describes the service procedures for each
section of periodic Maintenance.

BATTERY

Inspect Initial 1,000km and Every 5,000km
● The battery must be removed to check the electrolyte
level and specific gravity.
● Remove the seat.(Refer to page 3-2)
● Remove battery � lead at the battery terminal.
● Remove battery � lead.
● Remove battery from the frame.
● Check electrolyte for level and specific gravity. Add
distilled water, as necessary, to keep the surface of
the electrolyte above the LOWER level line ① but not
above the UPPER level line ②.
For checking specific gravity, use a hydrometer to deter-
mine the charged condition.
09900-28403
Standard specific gravity
An S.G reading of 1.22(at 20℃)or under means that the
battery needs recharging off the machine : take it off and
charge it from a recharger. Charging the battery in place
can lead to failure of the regulator/rectifier.
● To install the battery, reverse the procedure described
above.
WARNING:
When installing the battery lead wires, fix the � lead first and �
lead last
● Make sure that the breather pipe is tightly secured and
undamaged, and is routed as shown in the figure.
Hydrometer
12V 1.28 at 20℃
Breather pipe
Battery