Fan kit installation
1. Attach the fan assembly at the bottom edge of the in-
ner back with two (2) 1/4-20 x 3/4" hex head screws.
2. Attach snapstat to the mounting holes on the underside
of the bottom with two (2) 1/4-20 pan head screws.
3. Attach the rheostat holder (provided with the stove)
under the right front wing of the bottom heat shield with
two (2) #10 sheet metal screws.
4. Attach the rheostat to its holder by inserting the rheo-
stat control shaft through the holder hole. Install the
retaining ring and rheostat knob onto the shaft.
5. Secure the rheostat cable to the underside of the bot-
tom heat shield using the wire tie provided and the
hole at the right rear edge of the heat shield.
6. Fan will not operate until stove reaches approximately
109°F.
7. Plug blower cord into a grounded outlet. Do not re-
move ground prong from plug. Route power cord to
avoid heat from the stove or other damage. Do not
route cord under or in front of appliance.
Hole for Wire
Tie to Secure
Cable
Rheostat
Knob
Rheostat
Holder
Rheostat
Snapstat
Fig. 26 Fan installation (Kit # 2767).
installing or Removing catalyst
1. Remove the access cover by gently lifting up and pull-
ing out from the bottom edge. (Fig. 27)
2. Remove the inner cover by pulling it straight out. (Fig.
28)
3. Remove the catalyst by gently pulling it straight out.
(Fig. 29) Place the catalyst where the catalyst's ce-
ramic components will not be damaged.
30005295
Encore
®
FlexBurn
Fig. 27 Remove access cover.
Fig. 28 Remove inner cover.
Screws
ST848
Fig. 29 Remove catalyst.
2040 Non-Catalytic / Catalytic Woodburning Stove
Access
Cover
ST1187
Inner Cover
ST1187
remove access cover
ST1188
ST1188
remove inner cover
Remove Catalyst
ST1189
remove catalyst
ST1189