Symbol Definitions; Command/Response Table For Sis Commands - Extron electronics SW2 RGBHV User Manual

Sw rgb and sw yuv a series wideband and component video and audio switchers
Table of Contents

Advertisement

Remote Control, cont'd

Symbol definitions

X1
X2
X3
X4
X5
X6
X7
X8
X9

Command/Response table for SIS commands

Command
Input selection
Select video and audio input
Example (SW4 RGBHV A):
Example (SW6 RGBHV):
Select video input only
Select audio input only
(SW 2/4/6 RGBHV A only)
4-4
SW RGB and YUV A Switchers • Remote Control
ASCII to HEX Conversion Table
Space
Input and output numbers in commands may be entered as either 1-, 2-, or 3-
digit numbers. All input and output numbers are specified as 3-digit numbers
in the response.
=
CR/LF (carriage return/line feed) (0x0D 0A)
=
CR (carriage return, no line feed)
=
space
=
Input number
=
Input number
=
Input signal status
=
On/off
=
Numeric value
=
Audio gain
=
Audio attenuation
=
Controller firmware
=
Switch mode
ASCII Command Response
(host to switcher)
(switcher to host)
!
In
X1
3!
In3•All
5!
In5•All
&
In
X1
$
In
X1
0 through the maximum number of inputs (0 =
muted output)
1 through the maximum number of inputs
0 = no signal detected, 1 = signal detected
0 = off, 1 = on
-18 dB to +24 dB, each step = 1 dB
0 to 24
1 to 18
x.xx
1 = normal switch mode, 2 = autoswitch mode
Additional description
•All
Select input
X1
Select input 3 video and audio.
Select input 5 video.
•Vid
Select input
X1
breakaway).
•Aud
Select input
X1
(audio breakaway).
video and audio.
X1
video only (audio
X1
audio only
X1

Advertisement

Table of Contents
loading

Table of Contents