Routing The Aap Cables - Extron electronics HSA 400 US/Domestic User Manual

Hideaway surface access products
Hide thumbs Also See for HSA 400 US/Domestic:
Table of Contents

Advertisement

Maintenance and Modifications, cont'd
The flanged edges of the top of the surface enclosure
CAUTION
are bevelled to an ultra-fine thickness of less than
0.04 (4/100)" (approximately 1 mm). These edges
are soft and can be easily nicked or bent. Exercise
caution when handling and mounting the enclosure.
Mishandling can damage the appearance of the
enclosure.
The surfaces of the HSA enclosure have screws and
other protrusions that could damage fine furniture.
Do not rest the enclosure on unprotected furniture.
Remove the front panel from the enclosure.
6.
Disconnect any cables from the rear of the existing AAPs.
7.
Carefully pull the cables out through the bottom of the
surface mount enclosure.
On the underside of the table, remove the two bolts that
8.
secure the clamshell to the surface mount enclosure
(figure 3-5). Lift the enclosure out of the table.
IEC Power Cord
4 RJ-45 Connectors
Figure 3-5 — Removing the HSA 402 from the table
HSA 400/402 Series • Maintenance and Modifications
3-6
HSA 402
Mounting
Surface
AAP Cables
Clamshell
Flat Washer
Full Thread
Mounting Bolts
Perform the desired maintenance procedure.
9.
If the surface is not level, adjust the top surface. See
10.
"Adjusting the Top Surface Level", later in this chapter.
Carefully lower the HSA enclosure into the table opening.
11.
From the underside, bolt the clamshell to the enclosure
with the two bolts removed in step 8.
Connect the IEC power cord and RJ-45 cables to the
12.
connectors on the underside of the surface mount
enclosure.
Cable the rear of the AAPs that are installed on the front
13.
panel. Route the cables through the hole in the underside
of the surface mount enclosure and connect them to the
rear of the AAPs. If applicable, refer to the cabling
information in the AAP documentation.
Snap the interior RJ-45 connectors
14.
onto the rear of the front panel
bezel plug-ins.
Replace the front panel in the
15.
surface mount enclosure and secure
it in place with the hex head screws
that were removed in step 4. If you lose a
front panel screw, two spare screws are stored
in the underside of the clamshell.
Reconnect the interior AC power cable.
16.
To prevent wear and tear caused by cable movement,
17.
secure the AAP cables underneath the table. See "Routing
the AAP Cables" in chapter 2, "Installation".
HSA 400/402 Series • Maintenance and Modifications
3-7

Advertisement

Table of Contents
loading

Table of Contents