Maintenance and Modifications
The HSA surface mount enclosures can be modified in the
future to replace an AAP or to change the color or appearance of
the bezel plug-ins. The most probable corrective maintenance
procedures required are leveling the top surface and adjusting
its height and replacing the gas lift. Most of the maintenance
procedures require removing the surface mount enclosure from
the table.

Replacing an AAP

Replace one or more AAPs as follows:
Ensure that AC power is disconnected before
servicing the HSA unit.
On the underside of the clamshell and in the enclosure, cut
1.
the tie wraps that route the AAP cables out of the way.
Remove the four hex head screws on the right and left
2.
sides of the front panel (figure 3-1). Retain the screws. Lift
the panel away from the enclosure.
Remove two
Allen screws on each side.
Lift panel out
of enclosure.
Figure 3-1 — Removing the front panel
Disconnect any cables from the rear of the AAPs that are to
3.
be replaced. If a cable is no longer required in your
system, carefully pull the cable out through the bottom of
the surface mount enclosure and the clamshell.
HSA 400/402 Series • Maintenance and Modifications
3-2
Remove the AAP(s) to be replaced from the front panel by
4.
unscrewing the nuts on the rear of the panel that fasten the
plates to the faceplate (figure 3-2).
Front Panel
IN P
U T
S E
L E
C T
C O
A U
M P
D IO
U T
E R
Figure 3-2 — Mounting an AAP device
Cable the rear of the AAPs to be installed before attaching
5.
the AAPs to the enclosure. Route the cables through the
hole in the underside of the surface mount enclosure and
connect them to the rear of the AAPs. If applicable, refer
to the cabling information in the AAP documentation.
Insert each AAP's screws through the holes in the AAP
6.
opening of the front panel. Secure each AAP to the
enclosure with the provided captive washers and #4-40
nuts.
Replace the front panel in the surface mount enclosure and
7.
secure it in place with the hex head screws removed in
step 2. If you lose a front panel screw, two spare screws
are stored in the underside of the clamshell.
To prevent wear and tear caused by cable movement,
8.
secure the AAP cables underneath the table. See "Routing
the AAP Cables" in chapter 2, "Installation".