Installation, cont'd
Carefully lower the HSA enclosure into the hole to test the
7.
fit. If necessary, remove the enclosure and use a file or
rasp to enlarge or smooth the edges of the opening.
From the underside of the table, bolt the clamshell to the
8.
enclosure with two bolts of optimum length (included)
(figure 2-3).
Power Cord
2 RJ-45 Connectors
Figure 2-3 — Mounting the HSA 400 enclosure
Peel any remaining protective coating from the enclosure.
9.
HSA 400/402 Series • Installation
2-6
HSA 400
Enclosure
Mounting
Surface
AAP Cables
Clamshell
Flat Washer
Full Thread
Mounting Bolts

Cabling and Installing the AAPs

The space behind the AAP panel is limited. The on-line
Connectivity Configurator, available at
www.extron.com, offers guidance as to the fit of AAPs
into this space.
The various Extron single- and double-space AAP devices,
including the various RGB 580xi AAPs, can be mounted to the
HSA. See appendix A, "Reference Information", for
RGB 580xi AAP part numbers.
The screws needed for installing an AAP are built into its front
panel, so no additional screws are needed.
Ensure that AC power is disconnected before
servicing the HSA unit.
Remove the four hex head screws on the right and left
1.
sides of the front panel (figure 2-4). Retain the screws. Lift
the panel away from the enclosure.
Remove two Allen
screws ea. side.
Lift panel out
of enclosure.
Figure 2-4 — Removing the front panel from an
HSA 400 International
Cable the rear of the AAPs before attaching the AAPs to
2.
the enclosure. Route the cables through the hole in the
underside of the surface mount enclosure and connect
them to the rear of the AAPs. If applicable, refer to the
cabling information in the documentation for the AAP.