Cabling The Rj-45 Connectors - Extron electronics HSA 400 US/Domestic User Manual

Hideaway surface access products
Hide thumbs Also See for HSA 400 US/Domestic:
Table of Contents

Advertisement

Installation, cont'd
120-240
50/60 Hz 5A
Front Panel View
1A 1B
2
1A 1B
Underside View
Figure 2-7 — HSA 402 enclosure underside features
RJ-45 connectors — See "Cabling the RJ-45 connectors" on
1
the next page.
All RJ-45 connectors are teminated in accordance with
the TIA/EIA T 568 A standard.
AC power connector — Connect this power cord to the power
2
source.
For US domestic versions, this power cord is
permanently connected to the HSA.
Connect the power cord to a 125V AC, 60 Hz,
10A power source.
For international versions, this power cord is
a removable IEC power cord. Connect the
power cord to a 220-250V, 50-60 Hz, 10A
power source.
HSA 400/402 Series • Installation
2-10
HSA 402
120-240
50/60 Hz 5A
AUDIO
INPUT
COMPUTER
SELECT
H. SHIFT
RGB 580 xi SI AAP
1C 1D
3
1C
1D
The Universal AC outlet is fully compatible with
Europlug, British, Indian, Danish, and Italian plug
types. See the universal AC outlet guide on the Extron
Web site, www.extron.com, for compatibility details on
all plug types.
Cable access holes
3

Cabling the RJ-45 connectors

Plug one end of a twisted pair (TP) cable into each of these RJ-45
female connectors on the underside of the HSA (figure 2-6 on
page 2-9 and figure 2-7 on page 2-10). Connect the other end to
an appropriate telecommunications or data network or to an
Extron TP product.
An RJ-11 (telephone) jack can be plugged directly into
the RJ-45 jack.
Cables inside the HSA route the network cables from the front
panel to the underside of the enclosure. The bottom RJ-45
connections match up with the front panel RJ-45 connector
locations identified on figure 2-6 and figure 2-7. For example,
match the front panel RJ-45 (CAT 5/6) network, data, or
communications connection
connector
, match
with
1A
1B
Only connectors
If necessary, on the front panel, have a qualified service person
replace the connector icon by prying the old icon off of the
connector plug-in with an Extron Tweeker or small screwdriver
(figure 2-8) and snapping a new icon in place.
Icon Label
Figure 2-8 — Changing the connector icon
HSA 400/402 Series • Installation
with the underside RJ-45
1A
, and so forth.
1B
and
are present on the HSA 400.
1A
1B
2-11