Setup - MULTIQUIP Power WHISPERWATT DCA220SSJ Operation And Parts Manual

60hz whisperwatt generator
Hide thumbs Also See for Power WHISPERWATT DCA220SSJ:
Table of Contents

Advertisement

Battery
This unit is of negative ground DO NOT connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level are not
properly maintained. Add only distilled water when
replenishment is necessary.
DO NOT over fill. Check to see whether the battery cables
are loose. Poor contact may result in poor starting or
malfunctions. Always keep the terminals firmly tightened.
Coating the terminals with an approved battery terminal
treatment compound. Replace battery with only
recommended type battery.
The battery is sufficiently charged if the specific gravity of
the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Before charging the battery with an external electric source,
be sure to disconnect the battery cables.
Battery Cable Installation
ALWAYS be sure the battery cables (Figure 37) are properly
connected to the battery terminals as shown below. The Red
Cable is connected to the positive terminal of the battery,
and the Black Cable is connected to the negative terminal
of the battery.
CAUTION - BATTERY SERVICING SAFETY
ALWAYS disconnect the negative terminal FIRST and
reconnect negative terminal LAST.
Figure 37. Battery Connections
DCA-220SSJ/SSJU — OPERATION AND PARTS MANUAL — REV. #0 (02/04/14) — PAGE 51
DCA-220SSJ/SSJU — SETUP
When connecting battery do the following:
1. NEVER connect the battery cables to the battery
terminals when the MPEC Control Switch is in either
the MANUAL or AUTO position. ALWAYS make sure that
the MPEC Control Switch is in the OFF/RESET position
when connecting the battery.
2. Place a small amount of battery terminal treatment
compound around both battery terminals. This will ensure
a good connection and will help prevent corrosion around
the battery terminals.
NOTICE
If the battery cable is connected incorrectly, electrical
damage to the generator will occur. Pay close attention to
the polarity of the battery when connecting the battery.
CAUTION - BATTERY SERVICING SAFETY
Inadequate battery connections may cause poor starting
of the generator, and create other malfunctions.
Alternator
The polarity of the alternator is negative grounding type. When
an inverted circuit connection takes place, the circuit will be
in short circuit instantaneously resulting the alternator failure.
DO NOT put water directly on the alternator. Entry of water
into the alternator can cause corrision and damage the
alternator.
Wiring
Inspect the entire generator for bad or worn electrical wiring
or connections. If any wiring or connections are exposed
(insulation missing) replace wiring immediately.
Piping and Hose Connection
Inspect all piping, oil hose, and fuel hose connections for
wear and tightness. Tighten all hose clamps and check hoses
for leaks.
If any hose ( fuel or oil ) lines are defective replace them
immediately.