Connecting Alarms

Document 800-07067V5 Rev A
07/2013
®
HCD5 equIP
Series True Day/Night Network Box Camera Reference Guide
WARNING!
Do not exceed the maximum rating of 12 V DC, 0.5 A on alarm
output connections.
The network camera has one alarm input and one alarm output available to connect to
peripheral devices
(Figure
Figure 2-4
Alarm Connections
OUT
OUT
IN
IN
ALARM
Connect mechanical or electrical switches to the alarm input connection to allow
event-triggered recording. When alarm inputs are configured, the camera triggers an alarm
only when the normal state (open or closed) changes (see
on page
81
to configure the alarm inputs.
The network camera has a D/N Control setting which allows control of the moving IR cut
filter when there is a change in state from Normally Open to Normally Closed or from
Normally Closed to Normally Open for Alarm input (see
on page
81
for more information). In this way, the moving IR cut filter and the day/night
operation of the camera can be interlocked with external lighting changes using a common
controller such as a photocell or timer.
Figure 2-5
Normal Alarm States
Normally opened
Normally closed
Connect external devices such as sirens or flashing lights to the alarm output connector to
signal users of the camera that an alarm is activated. See
2-4).
Figure
2-5). See
Alarm Settings
Alarm Interlock Day/Night Switching
Figure 2-6
for alarm connection.