Profile A provides only an OFF delay of one (1) minute at
100% of the cooling demand airflow.
100% CFM
OFF
Profile B ramps up to full cooling demand airflow by first
stepping up to 50% of the full demand for 30 seconds. The
motor then ramps to 100% of the required airflow. A one (1)
minute OFF delay at 100% of the cooling airflow is provided.
100% CFM
50% CFM
OFF
1/2 min
Profile C ramps up to 85% of the full cooling demand airflow
and operates there for approximately 7 1/2 minutes. The
motor then steps up to the full demand airflow. Profile C
also has a one (1) minute 100% OFF delay.
OFF
Profile D ramps up to 50% of the demand for 1/2 minute,
then ramps to 85% of the full cooling demand airflow and
operates there for approximately 7 1/2 minutes. The motor
then steps up to the full demand airflow. Profile D has a 1/
2 minute at 50% airflow OFF delay.
OFF
100% CFM
OFF
1 min
100% CFM
OFF
1 min
100% CFM
OFF
Model
*CVM960604CX*
*CVM960805DX*
GCVM961005DX*
*MVM960603BX*
*MVM960805CX*
OFF
*MVM961005DX*
*MVM961155DX*
7. Select the heating speed for your model from the heating
speed chart in the Specification Sheet. The "adjust" setting
(already established by the cooling speed selection)
determines which set of speeds are available. The selected
speed must provide a temperature rise within the rise range
listed with the particular model.
8. Select the desired "heating" speed tap by positioning
switches 3 and 4 appropriately. Refer to figure above. Verify
CFM by noting the number displayed on the dual 7-segment
LED display.
In general lower heating speeds will: reduce electrical consump-
tion, lower operating sound levels of the blower, and increase the
outlet air temperature delivered to the home. The speeds avail-
able allow the blower performance to be optimized for the particu-
lar homeowner's needs.
41
Low
High
Tap
Stage
Stage
Stage
Cool
Cool
Heat
A
370
660
B
540
860
C
790
1150
1040
D
980
1470
1120
A
530
900
1110
B
730
1100
1200
C
930
1430
1270
D
1220
1880
1330
A
500
780
1220
B
740
1070
1250
C
920
1380
1300
D
1160
1780
1310
A
390
630
B
550
800
C
680
1000
D
800
1210
A
540
830
1140
B
750
1090
1190
C
980
1460
1270
D
1210
1800
1330
A
510
790
1230
B
710
1100
1260
C
910
1410
1300
D
1160
1830
1330
A
510
790
1230
B
710
1100
1260
C
910
1410
1300
D
1160
1830
1330
Airflow Table
Low
High
Stage
Heat
880
1220
970
1340
1460
1590
1600
1710
1800
1910
1730
1770
1840
1870
600
820
650
890
690
950
730
1030
1600
1690
1800
1890
1810
1850
1890
1940
1810
1850
1890
1940

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents