User Set Mode; Stun Function - Icom IC-F3022T/S Instruction Manual

Vhf/uhf transceiver
Table of Contents

Advertisement

USING [TX CODE ENTER] KEY:
q Select the desired TX code channel. (p. 12)
w Push [TX Code Enter] to enter the TX code edit mode.
• The digit to be edited blinks.
e Push [TX Code Enter] several times to select the desired
digit to be edited.
r Push [CH Up], [CH Down] or 10-keypad* to set the de-
sired digit.
t Push [TX Code Enter] to set the digit. The digit to the right
will blink automatically.
• When the 10-keypad* is used for setting, the digit to be edited
moves to the right automatically without pushing [TX Code Enter].
y Repeat r and t to input all allowable digits.
u After setting the last digit, push [TX Code Enter] to set the
code and return to the stand-by mode.
*10-key versions only
D DTMF transmission
If the transceiver has [DTMF Autodial] assigned to it, the
automatic DTMF transmission function is available. Up to 8
DTMF channels are available.
TO SELECT A TX CODE:
q Push [DTMF Autodial]— a DTMF channel appears.
w Push [CH Up] or [CH Down] to select the desired DTMF
channel.
e Push [DTMF Autodial] to transmit the DTMF code in the
selected DTMF channel.

■ User set mode

User set mode is accessed at power ON and allows you to set
seldom-changed settings. In this case you can "customize" the
transceiver operation to suit your preferences and operating style.
Entering the user set mode:
q While pushing and holding [Side2] and [Side3], rotate
[VOL] to turn the power ON. Then, push and hold [P0] for
1 sec. to enter user set mode.
w Push [P0] several times to select the appropriate item.
Then push [CH Up] or [CH Down] to set the desired level/
condition.
• Available set mode functions are Backlight, Beep, Beep
Level, SQL Level, Mic Gain, Battery Voltage Signal Moni
and Lone Worker.
e Rotate [VOL] to turn the power OFF to exit user set mode.
NOTE: User set mode is also available via a programma-
ble function key. Refer to "USER SET MODE KEY." (p. 8)

■ Stun function

When the specified ID, set as a killer ID, is received, the stun
function is activated.
When the killer ID is received, the transceiver switches to
the password required condition. Entering of the password
via the keypad is necessary to operate the transceiver again
in this case. (p. 9)