To Test Thermostat

WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR
SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND
VOID YOUR WARRANTY.
CAUTION: D
O NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW
T
HIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY
1. Place the COOL-OFF-HEAT
switch into the COOL position.
2. Press the
temperature setting is at least
3 degrees below the room
temperature. The air conditioning
system should turn on within
a few seconds.
NOTE: When in the COOL mode once the thermostat turns off, a built in 5-
minute delay prevents the system from turning on again. This protects the
compressor. No additional time delay relay is required. To override the 5-
minute delay for installation, press the RESET button.
3. Put the COOL-OFF-HEAT switch
into the OFF position. The air
conditioning system should turn off.
4. Put the COOL-OFF-HEAT switch
into the HEAT position.
5. Press the
temperature setting is at least
3 degrees above room temperature.
The heating system should turn on.
The fan may not turn on immediately,
depending upon the fan delay built
into the furnace.
6. Put the COOL-OFF-HEAT switch
into the OFF position. The heating
system should turn off. The fan may
continue to run for a short period
of time.
7. Put the
ON position. The blower fan should
turn on.
8. Put the
the AUTO position. The blower fan
should turn off.
button until the
button until the
AUTO-ON switch to the
AUTO-ON switch to
COOL-OFF-HEAT
COOL-OFF-HEAT
COOL-OFF-HEAT
COOL-OFF-HEAT
7
50°F (10°C).
.
AUTO - ON
AUTO - ON