Junction Box Installation - Heat & Glo CERONA-36 Owner's Manual

Installation and operation
Hide thumbs Also See for CERONA-36:
Table of Contents

Advertisement

D.

Junction Box Installation

If the box is being wired from the OUTSIDE of the
appliance:
• Loosen screw on the Romex connector, feed
the necessary length of wire through the
connector and tighten the screw.
• Make all necessary wire connections and
reattach the cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box
to the outer shell, rotate the junction box
inward to disengage it from the outer shell (see
Figure 10.2).
• Loosen the screw on the Romex connector, feed
the necessary length of wire through the con-
nector and tighten the screw.
• Pull the electrical wires from outside the
appliance through this opening into the valve
compartment.
• Make all necessary wire connections to the
receptacle and assemble the receptacle and
cover to the junction box.
JUNCTION
Figure 10.2
Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. A • 6/06
HEAT SHIELD
WHITE
BOX
GROUND WIRE
INSIDE BOX
BOTTOM PAN
Junction Box Detail
14/2WG
STRAIN RELIEF
CONNECTOR
FRONT OF
FIREPLACE
BLACK
COPPER GROUND
ATTACHED TO
GROUND
SCREW WITH
GROUND WIRE
NOTE: Do NOT wire
110VAC to wall switch.
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cerona-42

Table of Contents