Honeywell ADEMCO VISTA-40 Programming Manual page 7

2-partitioned security system
Hide thumbs Also See for ADEMCO VISTA-40:
Table of Contents

Advertisement

*80
*81
SYSTEM NON-ALARM CODES
Enter 00-09; B-F (11-15).
Default = 00 for all reports
*80 1st Digit
Close
Open
Low Battery
Low Battery Restore
AC Loss
AC Restore
Test
Power Up
Cancel
Program Tamper
*83
FIRST TEST REPORT TIME
[Day 00; hour 12; min 00] Days 01-07 Hours 00-23 Min 00-
59; 00 in all boxes = instant (Day 01= Monday)
*84
SWINGER SUPPRESSION
01-15 alarms
Must be "00" (disabled) for UL
*85
ENABLE DIALER REPORTS FOR PANICS & DURESS
1=enable; [0=disable]
*87
ENTRY WARNING
1=continuous; 0=3 beeps
*86
4208 MODULE ZONE ASSIGMENT
1 = allows 8 zones on one module (10-17), but prevents any
other polling loop expansion. 0 = all other setups.
*88
BURG. ALARM COMM. DELAY
1=16 seconds; 0=no delay
Must be "0" for UL installations.
*89
RESTORE REPORT TIMING
0=Instant; 1=At bell timeout if zone is restored; 2=when
system is disarmed. Must be "0" for UL installations.
*90
SEC. SUBS. ACCT #
Enter 00-09; B-F (11-15)
2nd Page Programming Fields
1*01
1*09
ASSIGN RESPONSE TYPE FOR ZONES.
Skip these fields. Use #93 Menu Mode, Zone
Programming to program the response types.
MISCELLANEOUS WIRELESS OPTIONS
Fields 1*28 - 1*31 are not applicable for UL installations.
1*28
RF TX LOW BATTERY SOUND
1=immediate; 0=when disarmed
1*29
RF TX LOW BATTERY REPORTING
1=enable; 0=disable
*81 2nd Digit
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[03]
.
995 996 999 Duress
[1]
[0]
[0]
[0]
|
|
|
[15 15 15 15]
(press *94)
[0]
[0]
1*30
RF RCVR CHECK-IN INTERVAL
02-15 times 2 hours; 00 disables supervision
1*31
RF XMITTER CHECK-IN INTERVAL
02-15 times 2 hours; 00 disables transmitter supervision
1*33
TOUCHTONE W/ROTARY BACKUP
1=enable; 0=disable
1*34
COMM. SPLIT REPORTING
0=no; 1=alarms and alarm restores primary, others secondary;
2=open/close, test secondary, others primary. See
comments if using with dual reporting.
1*40
1*41
NON-ALARM DIALER CODES
Enter 00-09; B-F (11-15).
Default = 00 for all reports
Time/Date Set or Event Log Reset
1*43
PERM. KEYPAD BACKLIGHT
1=enable; 0=disable When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
|
1*44
WIRELESS KEYPAD TAMPER
DETECTION
1=enable; 0=disable.
|
Must be "0" for UL installations.
1*45
EXIT DELAY SOUNDING
1=enable; 0=disable. Produces quick beeping during exit
delay if enabled.
NOTE: See page 32, "SOUND OPTION", prompt for
disabling the entry/exit beeps on individual keypads.
1*46
AUXILIARY OUTPUT MODE
Enter 0 for ground start output.
Enter 1 for open/close trigger.
Enter 2 for keypad-like sounding.
Enter 3 if AAV module is being used.
NOTE: Only one of the above options may be active within
the system.
1*47
CHIME ON EXTERNAL SIREN
1=enable; 0=disable
1*48
WIRELESS KEYPAD ASSIGNMENT
0=disable; enter partition in which RF keypad used, 1-2.
Must be "0" for UL installations.
1*49
SUPPRESS TX SUPERVISION SOUND
|
1=disable; 0=enable.
Must be "0" for UL installations.
1*52
SEND CANCEL IF ALARM + OFF
1=no restriction; 0=within bell timeout period only
1*53
DOWNLOAD CALLBACK
1=callback not required; 0=callback required.
1*57
5800 RF BUTTON GLOBAL ARM
1=enable; 0=disable
– 7 –
[06]
[12]
1*40 1st Digit
1*41 2nd Digit
|
Armed STAY
|
|
|
[0]
[0]
7
51 for
|
|
[0]
[0]
[0]
[0]
[0]
[0]
[1]
[0]
[0]
[0]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-128bpVista-250bpVista-128sia

Table of Contents