PROMPT
02 START: PARTN
ANY PARTITION
0
Do not use a zone programmed with an RF Button (Input Type BR) to STOP a relay. The system will not de-
activate the relay.
PROMPT
02 STOP: ZN LIST
00
02 STOP: ZN TYPE
NO RESPONSE
00
02 STOP: PARTN
ANY PARTITION
0
02 RESTRICTION
1=YES
0=NO
0
02 RELAY TYPE
V-PLEX
0
02 ECP ADDRESS
00
02 MODULE RELAY#
0
02 HOUSE CODE
A
00
02 UNIT CODE
00
When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt.
If you are defining a zone list, continue to the next section. If not, enter 00 + [✱] at the next two prompts. You will then be
asked "Quit Menu Mode?" Enter 1 for "Yes," 0 for "No." Then enter [✱]99 to exit programming completely.
Zone List Programming
After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO." prompt, you are asked to enter a zone
list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows:
PROMPT
ENTER Zn LIST ?
00=QUIT
00
EXPLANATION
If the starting event will be limited to occurring on a specific partition, enter the partition number (1-2) in
which the start event will occur. Enter 0 for any partition.
Press [✱] to continue.
EXPLANATION
If a zone list is being used to stop this relay action, enter the zone list number, 1-4. The restore of a zone
on the zone list stops the relay. If a zone list is not being used, enter 0.
Press [✱] to continue.
If a Zone Type/System Operation is being used to stop the relay action, enter the 2-digit code listed in the
Choices for Start/Stop System Operation chart.
Press [✱] to continue.
This is the partition to which the stop condition will be limited. Enter 0 for any partition. Enter 1-2 for specific
partition number.
Press [✱] to continue.
The system may have some devices that are not intended to be under end user control, such as relays
activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay.
Press [✱] to continue.
Enter 1 for (ECP) relay modules (4204). Enter 2 for X-10 devices.
Press [✱] to continue.
If you selected 1 (4204), enter the actual module's address (01-15) as set by its DIP switches. Up to 2
modules can be installed in a system.
Press [✱] to continue.
For 4204 Relay Outputs, enter the specific relay number on that module (1-4).
Press [✱] to continue.
The keypad will display the Start and Stop summary screens again.
Press [✱] to continue.
If you selected 2 for X-10 devices, enter the numerical equivalent of the House Code of the device, as
follows:
A=00
D=03
B=01
E=04
C=02
F=05
Enter the numerical unit code of the X-10 device (00-15).
Press [✱] to continue.
The keypad displays the Start and Stop summary screens again.
Press [✱] to continue.
EXPLANATION
Enter the zone list number 01-04. Enter 00 to quit.
G=06
J=09
H=07
K=10
I=08
L=11
– 24 –
M=12
P=15
N=13
O=14