Fujitsu PRIMERGY TX100 S3 Core Edition Operating Manual page 89

Headless server
Hide thumbs Also See for PRIMERGY TX100 S3 Core Edition:
Table of Contents

Advertisement

Ê Ensure that all memory modules and expansion cards are properly seated
in the slots.
Ê Ensure that all cables are connected correctly.
Ê Latch the bottom edge of the side cover to the server chassis.
Ê Close the side cover until it locks in place.
Ê Reconnect the AC power cord.
Ê Contact the Fujitsu Technology Solutions customer service team if the
problem persists.
The power LED flashes at low frequency (1/2 Hz, once every two seconds)
This error state indicates that the system is not able to boot from its local hard
disk drives. Typically, the server will then stop booting after the BIOS POST
phase displaying an error message like "Operating System not found". In order
to resolve the problem, proceed as follows:
Ê Terminate all applications and shut down the server.
I
If the server does not shut down properly, press and hold the On/Off
button for five seconds, until the server switches off.
Ê Disconnect the AC power cord from the system.
Ê Pull the locking lever and fold out the side cover.
Ê Unlatch and remove the side cover.
Ê Ensure that all data and power cables on the hard disk drives are connected
correctly.
Ê Ensure that all HDD SATA cables are connected correctly to the system
board.
Ê Latch the bottom edge of the side cover to the server chassis.
Ê Close the side cover until it locks in place.
Ê Reconnect the AC power cord.
Ê If the problem cannot be resolved, try booting the server from the
Maintenance & Recovery DVD, establish a VNC connection and create
PrimeCollect log files as described in section
Ê Contact the Fujitsu Technology Solutions customer service team and
forward the PrimeCollect log files for further analysis.
TX100 S3 Core Edition
Operating Manual
Troubleshooting and tips
6.4.1 on page
61.
89

Advertisement

Table of Contents
loading

Table of Contents